Cable Detection Equipment Factory shares that there are also technical specifications for charging pile cables.
Here they are:
1. The conductor
- cores: 2,3,4,5 control lines with or without signals - conductors belong to class 6 of EN60228
- tinned or not
- recommended line section: 0,5; 1; 1, 5; 2, 5; 4. 6; 10; 16 was
2. The isolation layer
Allow the conductor to be wound with an appropriate material isolation layer
3. The insulation
- conductors must be covered with specified insulating materials
- insulation must be extruded and must be solid and uniform. The insulation must be removed without damaging the insulation itself and the conductor or existing tin coating
- the specified value of insulation thickness should meet the standard. The average value of insulation thickness should be no less than the specified value. The thickness at the thinest part of insulation should be no less than the specified value of 90 taper -0,1mm
4. Core wire and filling
- core wire must be twisted
- center packing is allowed
5. Inner sheath (if any)
- stranded core wires must be covered with an inner sheath of the same material as the outer sheath or insulation
- the inner sheath must be extruded on the insulated core wire, allowing the gap between the embedded insulation cores to form a virtual circle
- no harmful effects shall occur between the inner sheath and the insulation
- the inner sheath should not adhere to the insulation core wire
- the specified thickness of the inner sheath must conform to the standard
6. Block
- the shield of bare or tin-plated copper wire shall be covered by an inner sheath
- the nominal diameter of copper wire should meet the standard set value
- the total number of twisted joints, twisted Angle and filling coefficient within 100mm shielding length shall meet the standard requirements
7. Sheath or outer sheath
- shielded or stranded conductor must be covered with specified sheath material
- the outer sheath must be single-layer extruded and must be tightly fitted but not adhered to the shield or core wire
- the specified value of jacket thickness should meet the standard.
The average value of the sheath thickness should be no less than the specified value. The thickness at the thinnest part of the sheath should be no less than the specified value of 85 gloss -0,1mm
That's all for the sharing, thanks for your reading, and we also supply Cable Detection Equipment for sale, if you have any demand for our products, just feel free to contact us.
Xingtai Longjia Electronics Technology Co.,Ltd.